Gas Chromatography LGC-B11 is a benchtop unit with advanced flow controller (AFC) technology. System has digital control mode and polar capillary columns to separate polar analytes. GC oven is capable of 9 temperature program ramps and hold steps, and features rapid cooling: 250 °C to 50 °C < 10 minutes. Accurate flow rate control via AFC has higher level repeatability of retention time and peak area, enabling specific level of analysis by means of dual FID detectors.
Specifications
Oven |
Maximum capacity |
22 L |
Temperature range |
RT + 5 ? to 400 ? |
Temperature accuracy |
± 0.1 ? |
Temperature program |
9-phase/ 10 platform |
Program total time |
9999.9 min |
Maximum temperature heating rate |
0.1 to 60 ?/ min |
Maximum cooling rate |
? 10 mins (250 to 50 ?) |
|
Sample injector |
Temperature range |
RT+ 7 ? to 420 ? |
Temperature control |
Automatic |
Injector type |
Column or split |
Maximum sample inlet |
3 pcs |
Carrier gas flow type |
Constant pressure |
Pre column pressure range |
0 to 400 kPa |
Pre column pressure accuracy |
0.1 kPa |
Mobile phase flow range |
H2: 0 to 200 ml/min, N2: 0 to 150 ml/min |
|
Detector |
Temperature range |
RT + 7 ? to 420 ? |
Maximum installation |
Dual detector |
Flame ignition mode |
Automatic |
Flame Ionization Detector (FID) |
Logarithmic amplifier
High voltage switch control
Baseline signal display
Ignition coil control
Detection limit: ≤3 ×10 to 12 g/s (Sample: n-hexadecane)
Baseline noise: ≤ 5 × 10 - 14 A
Baseline draft: ≤ 6 × 10 -13 A
Dynamic range: 10 7
RSD: ≤ 3 % |
|
Power supply |
AC 220 V ± 22 V, 50 Hz ± 0.5 Hz, 3000 W |
Packing dimension |
1020 × 660 × 740 mm |
Gross Weight |
82 kg |
Net weight |
70 kg |
Features
-
7-inch LCD display specifies temperature, gas flow and heating curve
-
H2 and N2 mobile gas phase with AFC and constant pressure gas flow type
-
Equipped with capillary analysis system and capillary split sampler
-
Injection system incorporates diaphragm cleaning, split flow and auxiliary gas adjustment
-
Standard unit for high-speed analysis with polar capillary column
-
PEG-20M and FFAP stationary phase polar capillary columns can be coupled
-
Dual FID detector with automatic flame ignition and baseline signal display
-
Self-diagnostic and automatic fault recognition function
-
Multi-core and 32-bit embedded hardware system ensures the reliable operation
-
Equipped with chromatography workstation software to process data
-
Memory function can store 20 sample test data
-
RS232 interface and LAN port
Applications
Suitable for analysis of trace toxic compounds, monitoring and research in environmental protection, atmosphere and water source pollution. It is widely used for petrol-chemistry, environmental protection, epidemic prevention, pharmacology and scientific research.