Description

Wet Film Gauge
W5001. Wet Film Gauge (aluminium) 25–2000μm (pack of 10)
 
The Wet Film Gauge will measure the paint thickness while the coating is still wet.
 
Manufactured in aluminium, the Wet Film Gauge can either be kept has a record for the wet film thickness taken or cleaned in solvents and reused.
 
Supplied in packs of 10.
 
Compliant to ISO 2808 and ASTM D4414.
 
 
Technical Specification
 
The Wet Film Gauge has thirty teeth with the following measurement range:  25, 50, 75, 100, 125, 150, 175, 200, 225, 250, 275, 300, 350, 400, 450, 500, 550, 600, 650, 700, 750, 900, 1000, 1150, 1250, 1400, 1500, 1650, 1800, 2000µm.
 
Wet film thickness measurement should be taken as soon as possible after the coating application by pressing the Wet Film Gauge onto the coated flat surface so it touches the substrate.  Allow sufficient time for the coating to wet the teeth before removing the Gauge.
 
The coating thickness can now be observed by looking at the base of the teeth.  The Coating Thickness measurement  lies between the coated tooth and next uncoated tooth.
 

Video

Standards

Models

Request for Quote