Distributor for 25+ Global Partners
+91-22-40030990 +91-22-68286323 info@polytechinstruments.com
Type at least 2 characters, or press Enter to see all matching products
Labtron Equipment Ltd

Gas chromatography mass spectrometry GC_MS_879

Analytical Equipment

Gas chromatography mass spectrometry GC-MS is a high precision Gas chromatograph mass spectrometer with pre-filter mass analyzer and electron multiplier ensuring high sensitivity. Desorption for solids is performed at controlled temperature between 100 ~ 350 °C with a flow rate of 1 to 1.

Full Description

Gas chromatography mass spectrometry GC-MS is a high precision Gas chromatograph mass spectrometer with pre-filter mass analyzer and electron multiplier ensuring high sensitivity. Desorption for solids is performed at controlled temperature between 100 ~ 350 °C with a flow rate of 1 to 1.5 ml / min. With seven stage temperature programming and an interface temperature of 450 °C the analysis is sensitive and specific.

Specifications

Gas Chromatography SpecificationsModel No GC-87 Flow rate 1 ~ 1.5 ml / min Maximum flow rate 10 ml / min Inlet temperature 450 °C Pressure range 0 ~ 100 psi Heating rate Upto 120 °C / min Room temperature 4 °C ~ 450 °C Pressure control mode Electronic pressure control ( Supports CV and CC ) Split mode Split / split less Split ratioModel NoGC-87Flow rate1 ~ 1.5 ml / minMaximum flow rate10 ml / minInlet temperature450 °CPressure range0 ~ 100 psiHeating rateUpto 120 °C / minRoom temperature4 °C ~ 450 °CPressure control modeElectronic pressure control ( Supports CV and CC )Split modeSplit / split lessSplit ratio1000 : 1Temperature programming7 stages / 8 platformsAuto samplerOptional
Model NoGC-87
Flow rate1 ~ 1.5 ml / min
Maximum flow rate10 ml / min
Inlet temperature450 °C
Pressure range0 ~ 100 psi
Heating rateUpto 120 °C / min
Room temperature4 °C ~ 450 °C
Pressure control modeElectronic pressure control ( Supports CV and CC )
Split modeSplit / split less
Split ratio1000 : 1
Temperature programming7 stages / 8 platforms
Auto samplerOptional
Mass Spectrometry SpecificationsModel No MS-89 Mass range 1.5 ~ 1000 amu Ion – source temperature 100 °C ~ 350 °C GC-MS interface temperature 450 °C Scan rate Upto 10000 amu/s Stability ± 0.10 amu / 48 hrs. Filament emission current 0 ~ 350 µA EI source ionization energy 5 eV ~ 250 eV Resolution Unit resolution Detector High energModel NoMS-89Mass range1.5 ~ 1000 amuIon – source temperature100 °C ~ 350 °CGC-MS interface temperature450 °CScan rateUpto 10000 amu/sStability± 0.10 amu / 48 hrs.Filament emission current0 ~ 350 µAEI source ionization energy5 eV ~ 250 eVResolutionUnit resolutionDetectorHigh energy dynode electron multiplierSensitivityFull scan ( S / N is ≥ 30 : 1 )VacuumTurbo molecular pump ( 67 L/s )
Model NoMS-89
Mass range1.5 ~ 1000 amu
Ion – source temperature100 °C ~ 350 °C
GC-MS interface temperature450 °C
Scan rateUpto 10000 amu/s
Stability± 0.10 amu / 48 hrs.
Filament emission current0 ~ 350 µA
EI source ionization energy5 eV ~ 250 eV
ResolutionUnit resolution
DetectorHigh energy dynode electron multiplier
SensitivityFull scan ( S / N is ≥ 30 : 1 )
VacuumTurbo molecular pump ( 67 L/s )

Features

  • Column flow rate is 1 ~ 1.5 ml / min
  • Maximum flow rate is 10 ml / min
  • Simultaneous analysis with different components increasing productivity
  • Electronic flow control system
  • Mass analyzer with pre-filter reducing quadruple filtration
  • Turbo molecular pump vacuum system for stability and reliability
  • Software controlled auto sampler , gas chromatograph and mass spectrometer
  • Screens and quantifies more than 1000 compounds in a single run

Application

Used in identifying and quantifying volatile organic compounds in mixtures, testing residual solvents, identification of trace impurities in liquids or gases, evaluating extracts from plastics, contaminants on semiconductor wafers or other technology products.